Genetic Engineering & Biotechnology News

AUG 2014

Genetic Engineering & Biotechnology News (GEN) is the world's most widely read biotech publication. It provides the R&D; community with critical information on the tools, technologies, and trends that drive the biotech industry.

Issue link: http://gen.epubxp.com/i/350894

Contents of this Issue

Navigation

Page 31 of 45

30 | AUGUST 2014 | GENengnews.com | Genetic Engineering & Biotechnology News H. Tschiersch, G. Liebsch, L. Borisjuk, A. Stangelmayer, and H. Rolletschek Microbial and cell/tissue cultivations play major roles and serve as important tools in biological and medical research. Knowledge about the local metabolic activity of cells and structures within colonies may assist in understanding and controlling complex growth processes. One key parameter in cultivation con- trol is oxygen. Oxygen consumption or production can give valuable information about the metabolic status of a culture. Thus, precise oxygen measurement systems are indispensable. However, conventional techniques, e.g., electrodes, only allow single-point measure- ments, lacking the spatial information about oxygen distribution in the sample. Even con- ducting transect measurements with oxygen microsensors cannot completely overcome this limitation. The VisiSens TM A1 system combines planar fuorescent sensor foils with digi- tal camera technology, and now allows two-dimensional assessment of oxygen dis- tribution across the sample surfaces. The fuorescent sensor foils are non-toxic and do not consume oxygen during the mea- surement process. Information over a whole area can be recorded with μm resolution for extended measurement periods. The sensor foils are read out, contactless with a compact fuores- cence microscope. It can be easily installed inside an incubator and is controlled from the outside by PC or notebook (Figure 1). Being able to visualize and evaluate changes in oxygen partial pressure due to metabolic and diffusion processes makes Vi- siSens an applicable tool for cell and tissue culture monitoring. We tested this measure- ment technology and investigated oxygen distribution in different plant tissues. We also tried it in a nonplant application. In the experiment described here E. coli was used as a model microorganism. The culture was monitored with the VisiSens A1 system inside the incubator, and the oxygen consumption of single bacteria colonies was visualized. Materials & Methods At the start and the end of the experiment the VisiSens oxygen sensor foil (SF-RPSu4, PreSens) was calibrated by recording images of both a sodium sulfte solution (0% air sat- uration) and of air-saturated distilled water (100% air saturation). E. coli colonies were grown on an agar plate, and the sensor foil was put directly on the culture. The VisiSens detector unit (DU01) was installed inside the incubator and controlled from the outside with a laptop. Detector unit control and subsequent image analysis were realized with VisiSens AnalytiCal 1 software. Image recording was started immediately af- ter the culture was put in the incubator for an incubation period of 20 minutes; images were taken at an interval of 30 seconds. Imaging of E. coli Colonies Short-term incubation (5–20 minutes) with the oxygen sensor resulted in clear oxy- gen distribution images, where single colo- nies were identifable by their oxygen con- sumption (Figure 2). The oxygen concentration at the location of the colonies decreased rapidly within 20 min (Figure 3). The oxygen images further reveal how the oxygen decrease depends on the dis- tance to other colonies. Driven by diffusion and therefore by oxygen consumption of mul- tiple neighboring E. coli colonies the oxygen level inside the medium also changes over time. Conclusion VisiSens is able to visualize different sites within a multiwell plate or Petri dish. Ap- plied to microbial culture it is possible to distinguish oxygen consumption of single colonies. By visualizing oxygen distributions across the sample and its changes over time valuable information can be gained, which can be used to monitor the metabolic status or to modulate oxygen supply to better con- trol certain processes in cell or tissue culture. The use of VisiSens facilitates the study of respiratory dynamics and will contribute to a better understanding in many application felds, like the screening for respiratory phe- notypes in yeast. Imaging Microbial Culture O 2 Consumption BIOPROCESSING Metabolic Activity of E. coli Monitored Inside the Incubator with the VisiSens TM A1 H. Tschiersch, L. Borisjuk, and H. Rolletschek are researchers in the dept. of molecular genetics, Leibniz Institute of Plant Genetics. G. Liebsch (gregor.liebsch@ presens.de) is head of R&D; imaging solutions and A. Stangelmayer is CEO at PreSens. Website: www.presens.de. Figure 2. Oxygen image of E. coli colonies growing on agar. Yellow color indicates high oxygen; blue color, low oxygen concentrations. Figure 1. VisiSens A1 installed inside an incubator for noninvasive oxygen monitoring in a multiwell plate. The device is controlled from outside via notebook. Figure 3: Time series recordings of E. coli colonies during short- term incubation. Oxygen distribution changes and consumption over time can be clearly determined. Yellow color indicates high oxygen; blue color, low oxygen concentrations. Tutorial

Articles in this issue

Links on this page

Archives of this issue

view archives of Genetic Engineering & Biotechnology News - AUG 2014